A. Tools and consumable materials
- 2 isolating valves
ABAB
Validity : Electrohydraulic generator "L.H.C." 32-35-0 Page 204
1 (CA) JUN 01
 
- 1 pressure gage
- 1 three-way union
- 3 high pressure pipes
- 1 battery 24 volts or constant voltage electric supply
- Electric wiring
- 1 ammeter
- 1 voltmeter
- 1 control switch
- Hydraulic fluid (TB 02-001)
B. Procedure
1) Remove the electrohydraulic generator - refer to Paragraph 2.
2) Connect the electrohydraulic generator according to Figure 202.
3) Open the two isolating valves and run motor in both directions to purge air from test system.
4) Close isolating valve (8). Run motor to check high pressure and electric consumption - see charts hereafter.
5) Run motor to the low pressure direction. The pressure has to reach zero.
6) Close isolating valve (6). Open isolating valve (8). Run motor to check low pressure and electric consumption - see charts hereafter.
7) Run motor to the high pressure direction. The pressure has to reach zero.
NOTE : If the recommended pressures are not reached, replace the corresponding valves.
Voltage Electrohydraulic
generator Low pressure High pressure
  MIN MAX MIN MAX
24 V 1117-04 Amdt A or
1117-05 Amdt A 100 bars or
1450 psi 120 bars or
1740 psi 100 bars or
1450 psi 120 bars or
1740 psi
 1117-04 Amdt B or
1117-05 Amdt B 100 bars or
1450 psi 120 bars or
1740 psi 125 bars or
1810 psi 135 bars or
1960 psi
 1117-04 Amdt C or
1117-05 Amdt C 40 bars or
580 psi 45 bars or
650 psi 125 bars or
1810 psi 135 bars or
1960 psi

Voltage Electrohydraulic
generator Extension (LP) Retraction (HP)
24V 1117-04 Arndt A or B
or
1117-05 Arndt A or B I < 30 A I < 30 A

ABAB
Validity : Electrohydraulic generator "L.H.C." 32-35-01 Page 205
(CA) JUN 01
 
1 - Voltmeter
2 - Electrohydraulic generator
3 - Distribution plate
4 - Pipe
5 - Pressure gage [(0 to 2900 psi) (0 to 200 bars)]
6 - Isolating valve, high pressure system
7 - Three-way union
8 - Isolating valve, low pressure system
9 - Pipe
10 - Switch
11 - Ammeter (0 to 100 A)
12 - Battery 24 volts or constant voltage electrical supply
Electrohydraulic generator - Inspection / Check
Key to Figure 202
ABAB
Validity : Electrohydraulic generator "L.H.C." 32-35-01Page 206
(cA) JUN 011
 
BRANCHER AU FIL MARRON : BASSE PRESSION CONNECT TO BROWN WIRE : LOW PRESSURE
 