CONNECT TO BLUE WIRE : HIGH PRESSURE
Electrohydraulic generator - Adjustment / Test
Figure 203
 
Electrohydraulic generator - Adjustment / Test
Figure 204
AAAA
Validity : Electrohydraulic generator
"PRESTOLITE" 32 35 01Page 208
(BA) JUN 011
 
7) Close isolating valve (6). Open isolating valve (8). Run motor to the low pressure direction. Check low pressure setting and current draw specifications. Pressure should drop to 0 when motor is stopped.
8) Close isolating valve (8). Open the isolating valve (6). Run motor to the high pressure direction until pump develops maximum pressure, then stop motor.
Use the hand-pump to develop enough pressure to cause the relief valve to open. Check this pressure against specifications. Slowly open isolating valve (8) to release pressure.
9) Run motor to the high pressure direction. Adjust isolating valve (8) to obtain 1000 psi (69 bars) pumping pressure. Check the current draw of the motor. Current draw must not exceed 35 amperes for a 14-volt circuit and 30 amperes for a 28-volt circuit.
10) Close isolating valve (8). Run motor to the high pressure direction until pump develops maximum pressure, then stop motor. Wait about 5 seconds, then momentarily run motor again. At this point the pump should have developed its regulated high pressure setting and should be holding that pressure. If pressure drops more than 300 psi (20 bars) within 5 minutes, momentarily run motor again to obtain maximum pressure, then check that the pressure drop does not exceed 400 psi (28 bars) within 15 minutes. Make certain pressure drop is not being caused by loose fittings or leaking valves.
NOTE : Summary chart of the pressures provided by various electrohydraulic generators
Voltage Electrohydraulic
generator Low pressure (psi) High pressure (psi) Overpressure (psi)
  MIN MAX MIN MAX MIN MAX
12V HYC 5005 500 800 2000 2500 2000 2500
 HYC 5112 525 800 2000 2500 2000 2500
24 V HYH 5003 880 1250 1600 2000 3700 4000
 HYH 5001 850 1250 1600 2000 3700 4300

4. INSPECTION / CHECK - ELECTROHYDRAULIC GENERATOR (Figure 205)
A. Tools and consumable materials
- Hydraulic fluid (TB 02-001)
B. Procedure
1) Lubrication
At overhaul, saturate the grease-sealing felt around the commutator end bearing with hydraulic fluid (TB 02-001). Allow excess hydraulic fluid to drain off before assembling motor. Lubricate the drive end of the armature shaft to prevent damage to the 0-ring in the reservoir housing.
2) End play
Adjust to .005 in (0.13 mm) minimum with thrust washers on the drive end of the shaft between the armature and reservoir housing. Make certain the steel thrust ball is located in the armature shaft end on commutator side before assembling the motor.
 