6) Make sure the message "GOOD" is displayed for 3 seconds.
NOTE : If the word "BAD" and an error message appear, it means that the indicator does not
operate correctly. In this case, remove it and send it to the manufacturer.
7) Make sure "K" factor and the unit of measure are displayed.
8) Make sure the maximum quantity of usable fuel is displayed.
9) Make sure software version is displayed.
10) End of the test and return to continuous display of fuel flow.
11) Wait for one minute min. then open main switch-breaker.
12) Disconnect the ground power unit - refer to 24-40-00.
ABAB
Validity : With SHADIN 912041T-38D fuel flowmeter 73-30 03Page 503
(CA) SEP 02
 
1 - Fuel flow indicator
2 - Flow transmitter
3 - "K" factor
4 - "CAUTION" red adhesive label
 
SW SW SW SW
1 2 3 4
EiCi®®0)
4
Fuel flow indicator - Adjustment test
Figure 501
ABAB
Validity : With SHADIN 912041T-38D fuel flowmeter Page 504
73-30-03 (CA, SEP 02

 


 