曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
5) Remove defective connecting plug (4). Remove teflon tape and install a blanking cap or plug. 6) Remove cap (6) of defective connecting plug (4). Remove teflon tape. 7) Install cap (6) with teflon tape (TB 09-901) on new connecting plug (4). Torque - refer to 20-00-01. 4. INSTALLATION OF AN OXYGEN CONNECTING PLUG (Figures 402 and 402A) A. Tools and consumable materials - Teflon tape (TB 09-901) - Surface plate - White paint B. Procedure 1) Apply the oxygen system servicing procedure - see Page 301. 2) Remove blanking caps and plugs, install connecting plug (4) with teflon tape (TB 09-901). 3) Install oxygen distribution assembly (3) on a surface plate and check for connecting plug (4) perpendicularity. Adjust its position if necessary. 4) Install nuts (7) and (8) against connecting plug (4) body - see Detail A. 5) Position oxygen distribution assembly (3) on upper duct (1). 6) Screw covers (9) until they are flush with upper part of connecting plugs (4). 7) Tighten nuts (8) and (7). 8) Make sure all the tools and materials are removed and the work area is clean and free from debris. 9) Install upper duct - refer to 25-15-00. NOTE : With white paint, mark pipe unions, caps and nuts. AAAA Validity : With "EROS" oxygen system 35-00-00 Page 403 (BA) JUN 04 Oxygen cylinder — Removal / Installation Figure 401 1 - Upper duct 14350001AADBWZ14100 Oxygen connecting plug — Removal / Installation |