Validity : With "PURITAN-BENNETT" oxygen system Page 504
35 00 00
_ (CA) JUN 04
 
OXYGEN
INSPECTION / CHECK
WARNING : OBSERVE ALL THE SAFETY PRECAUTIONS DESCRIBED PAGE 301.
CAUTION : OXYGEN SYSTEM SERVICING MUST BE PERFORMED BY QUALIFIED PERSONNEL.
1. CHECK OF OXYGEN SYSTEM TIGHTNESS
A. Tools and consumable materials
None
B. Procedure
1) Check tightness of oxygen system one hour minimum after oxygen cylinder charging to avoid pressure variations due to oxygen temperature variations.
2) Make sure that the main switch-breaker is open.
3) Set the cabin oxygen control lever to "ON".
4) Check tightness of oxygen system on the cabin pressure gage. Any leak is detected by a decrease of the pressure value indicated by the pressure gage.
NOTE : Check duration is approximately one hour.
5) If a leak is found, perform leak test - see Page 501.
6) Set cabin oxygen control lever to "OFF".
2. CHECK OF OXYGEN SYSTEM
A. Tools and consumable materials None
B. Procedure
1) Check system for cleanliness.
2) Check oxygen cylinder for :
- corrosion,
- shocks or distorsions,
- attachment condition.
3) Check pipes and unions for :
- corrosion,
- shocks, distorsions or friction,
- presence of teflon tape and white paint marks.
4) Check tightness of oxygen system - see Paragraph 1.
5) Check that oxygen cylinder ventilation is correct.
WA
Validity : S / N 1 - 9999 35 00 00Page 601
(BA) JUN 04
 
PAGE INTENTIONALLY LEFT BLANK
AMA
Validity : S / N 1 - 9999 35 00 00Page 602
(BA) JUN 04
 
OXYGEN PIPES
SERVICING
WARNING : OBSERVE ALL THE SAFETY PRECAUTIONS DESCRIBED IN 35-00-00.
CAUTION : OXYGEN SYSTEM SERVICING MUST BE PERFORMED BY QUALIFIED PERSONNEL. 1. REPLACEMENT OF A PIPE AND/OR UNION ON OXYGEN SYSTEM
A. Tools and consumable materials
- Blanking caps and plugs
- Cleaning agent (TB 11-913)
- Teflon tape (TB 09-901)
- Nitrogen (TB 05-913)
- Steam degreaser
- White paint
B. Procedure
1) Apply the oxygen system servicing procedure - refer to 35-00-00.
2) Remove defective pipe and/or union. Install blanking caps and plugs on pipes and unions as soon as they are disconnected to avoid system contamination.
3) Before installation of a pipe and/or union, clean, degrease and dry the component :
a) Clean and degrease pipe and/or union with cleaning agent (TB 11-913) by immersion or using steam degreaser.
b) Carefully dry pipe and/or union with nitrogen (TB 05-913). There must neither not remain traces of humidity (risk of corrosion and risk of equipment icing) nor traces of cleaning agent (incommoding vapors and risk of explosure).
 