It is located on the rear bulkhead of the baggage compartment. It supplies the system with oxygen with a pressure reduced to approximately 75 psi (5 bars) with a pressure reducing valve.
The pressure reducing valve is equipped with a charging valve and a pressure gage.
B. Oxygen masks
Oxygen masks are stored in headrests.
With regulated-flow type front seat masks
The front seat masks are pressure-demand types and equipped with a microphone. The regulator consists of a two-position selector : "NORMAL" and "100 %".
The passenger masks are of constant-flow type.
 
On each oxygen mask, a flow indicator is integrated to the supply pipe. When pressure is normal, a green range appears and when pressure is low, a red range appears.
With constant-flow type front seat masks  The oxygen masks are constant-flow type.
On each oxygen mask, a pressure indicator is integrated to the supply pipe. When pressure is normal, a green range appears and when pressure is low, a red range appears.
The front seat masks are equipped with a microphone.
C. Oxygen control lever
The oxygen control lever allows opening and closing of oxygen cylinder through a semi-rigid control. It is located on the overhead panel.
D. Pressure gage
The pressure gage allows the pilot to check the oxygen cylinder charging level. It is connected to the oxygen cylinder by a high pressure capillary line. It is located on the overhead panel.
E. Oxygen connecting plugs
The oxygen connecting plugs (for quick connection) are located on the upper duct. They allow to connect oxygen masks to ensure oxygen supply.
1 - Oxygen lever control
2 - Pressure gage
3 - Headrest : storage of FWD mask
4 - Headrest : storage of rear mask
5 - Oxygen cylinder
6 - Oxygen control
7 - Low pressure outlet union
8 - Low pressure system (oxygen supply)
9 - Pressure gage supply system (overhead panel)
10 - Bonding strap
11 - Oxygen connecting plugs
12 - Overpressure valve
13 - Control mechanism
14 - Pressure gage (cylinder)
15 - Oxygen cylinder attaching clamp
16 - Charging valve
17 - High pressure outlet union
18 - Pressure reducing valve
Oxygen - Schematic
Key to Figure 1
 

 
Oxygen - Identification and location of components
Figure 2 - With regulated-flow type front seat masks
 
Oxygen - Identification and location of components
Figure 2A - With constant-flow type front seat masks
ABAB
Validity : With "PURITAN-BENNETT" oxygen system 35-00-00Page 5
(CA) JUN 04
 
PAGE INTENTIONALLY LEFT BLANK
ABAB
Validity : With "PURITAN-BENNETT" oxygen system 35 00 00 (CA) jPu agNe06 4
 
OXYGEN
SERVICING
1. SAFETY PRECAUTIONS
 