 PAGE VALIDITY
 501 With
 501 "PURITAN-BENNETT"
 501 oxygen system
501
501
502
A. Tools and consumable materials  502 
B. Procedure  502 
OXYGEN 35-00-00(BA) 601 1 - 9999
ADJUSTMENT / TEST  601 
1. CHECK OF OXYGEN SYSTEM TIGHTNESS  601 
A. Tools and consumable materials  601 
B. Procedure  601 
2. CHECK OF OXYGEN SYSTEM  601 
A. Tools and consumable materials  601 
B. Procedure  601 
OXYGEN PIPES 35-00-01(BA) 301 1 - 9999
SERVICING  301 
1. REPLACEMENT OF A PIPE AND/OR UNION ON   
OXYGEN SYSTEM  301 
A. Tools and consumable materials  301 
B. Procedure  301 

ADAA
Validity : S / N 1 - 9999 35 TC (EA) Page 3 JUN 04
 
PAGE INTENTIONALLY LEFT BLANK
I ADAA
Validity S / N 1 - 9999 35 TC (EA) Page 4 JUN 04
 
OXYGEN
DESCRIPTION AND OPERATION
1. GENERAL (Figure 1)
The oxygen system provides the oxygen necessary for four persons for flights at high altitude.
The system includes :
- an equipped oxygen cylinder,
- oxygen masks,
- an oxygen control lever,
- a pressure gage,
- oxygen connecting plugs,
- oxygen hoses and lines.
2. LOCATION (Figure 2)
COMPONENT QTY AREA ACCESS DOOR REFERENCE
Oxygen cylinder 1 240 219 35-00-00
Oxygen masks 4 230 / 35-00-00
Oxygen control lever 1 241 / 35-00-00
Pressure gage 1 241 / 35-00-00
Oxygen connecting plugs 4 236 / 35-00-00
Oxygen hoses and lines / 230/240 / 35-00-01

3. DESCRIPTION
A. Oxygen cylinder
The steel oxygen cylinder has a capacity of 65.7 cu.ft (1860 liters) and a maximum pressure of 1850 psi (127 bars) at 70°F (21°C).
It is located on the rear bulkhead of the baggage compartment. It supplies the system with oxygen with a pressure reduced to approximately 75 psi (5 bars) with a pressure reducing valve.
The pressure reducing valve is equipped with a charging valve and a pressure gage.
B. Oxygen masks
Oxygen masks are stored in headrests.
The front seat masks are pressure-demand types and equipped with a microphone. The regulator consists of a two-position selector : "NORMAL" and "100 %".
The passenger masks are of constant-flow type and can be set for two flow rates :
- flow selection ring on "LO" position : flow 0.467 U.S Gal/min to be used up to 17500 ft.
 
中国通航网 www.ga.cn
通航翻译 www.aviation.cn
本文链接地址:TB20 MAINTENANCE MANUAL 35 氧气 TB20飞机维护手册(3)
 