7.1. VM 1000 System General
The following provides a general description for use of the VM 1000 as it pertains to the operation of the DA20-C1.  Features such as “Autotrack” “Lean Mode” and “EC 100” are described in detail in the VISON MICRO SYSTEM owners manual P/N 5010002.  Copies of the manual can be obtained through.
Vision Micro Systems Inc. 4071 Hannegan Suite T Bellingham, Washington 98226 Phone (360) 714-8203 Fax (360) 714-8253
7.2. Tachometer
The tachometer system provides an analog display and a four place digital display.  Color range marks provide a quick reference to monitor normal, and red line engine RPM.
RPM: The digital display resolution is 10 RPM.
Engine Hours: When the engine is off, the digital display shows the total accumulated engine hours to a maximum of 5999.9 hours.  Engine hours are accumulated any time RPM is greater than 1500.
A warning alert activates when the RPM redline is reached.  The VM 1000 display will flash, if installed, the EC100 displays the warning and an audible tone is heard.

7.3. Manifold Pressure
The manifold pressure system provides an analog display and a three place digital display.  The full sweep analog display resolution is 1" Hg.  The digital display resolution is 0.1" Hg.
A warning alert activates when the manifold pressure redline is reached. The VM 1000 display will flash, if installed, the EC100 displays the warning and an audible tone is heard.
7.4. Oil System
Oil temperature and oil pressure are displayed continuously on an analog and a digital display.
Oil Pressure: As oil pressure rises, the analog display increases proportionately.  The digital display reads in increments of 1 PSI.  A warning alert activates whenever the oil pressure redline is reached. The VM 1000 display will flash, if installed, the EC100 displays the warning and an audible tone is heard.
Oil Temperature: As oil temperature rises, the analog display increases proportionately. The digital display reads in increments of 1 degree Fahrenheit to a maximum of 300 degrees. A warning alert activates whenever the oil temperature rises above the redline. The VM 1000 display will flash, if installed, the EC100 displays the warning and an audible tone is heard.
7.5. Fuel Pressure
Fuel Pressure:  As fuel pressure rises, the analog display increases proportionately.  The digital display reads in increments of 1 PSI.  A warning alert activates whenever the fuel pressure redline is reached. The VM 1000 display will flash, if installed, the EC100 displays the warning and an audible tone is heard.
7.6. Fuel Computer System
The fuel computer portion of the VM 1000 is not operational on the DA20-C1
7.7. Electrical System
Voltage is displayed both analog and digitally. Full color range marks provide a quick reference for fast analysis of voltage levels.  As voltage rises, the analog display increases proportionally. The digital readout is at 0.1 volt resolution. A warning alert activates whenever the voltage redline is reached. The VM 1000 display will flash, if installed, the EC100 displays the warning and an audible tone is heard.
 