返回首页
当前位置: 主页 > 通航资料 > TB >

TB20 MAINTENANCE MANUAL 24 COMMUNICATIONS TB20飞机维护手册 电源(43)

时间:2011-10-31 12:26来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
  
   il Stall warning indicator (Alarm box)
   
   ...- Strobe lights
  Crx. 
   As— (Magneto selector) Starter
   
   
  0-x-6 Fuel pump
  -b.
0" a— Turn and bank indicator
U
S   
   ..— Navigation lights
  Cr-C-L a..-- Heated pitot
   a.•-- Taxi light
   
  Creb Lighter
   a— Blower
  (S-7) 
   H.F.

Distribution - Electrical distribution
Figure 3
ACAA
Validity : S / N 1 - 822, 850 - 887, 889 - 947 24-50-00(DA) 5
(DA) OCT 02
 
PAGE INTENTIONALLY LEFT BLANK
ACM
Validity : S / N 1 - 822, 850 - 887, 889 - 947
Page 6
24-50-00
(DA) OCT 02
 
DISTRIBUTION
DESCRIPTION AND OPERATION
1. GENERAL
The distribution is the part of the system which connects the DC current source to the utilization circuits. This sub-system consists of the following main elements :
- fuses of PL3 fuse panel,
- bus bars,
- "pull-off" type circuit-breakers of PL1 circuit-breaker panel,
- circuit-breakers of PL1 circuit-breaker panel,
- switch-breakers of PL2 central pedestal.
2. LOCATION (Figure 1)
COMPONENT QTY AREA ACCESS DOOR REFERENCE
Fuses / 200 211L
212L 24-50-00
Bus bars 3 (Std)
1 (Opt.) 200 232L 24-50-00
"Pull-off" type circuit-breakers / 200 232L 24-50-00
Circuit-breakers / 200 232L 24-50-00
Switch-breakers / 200 252 24-50-00

3. DESCRIPTION (Figures 2 and 3)
A. Fuses
Fuses inserted in PL3 panel located on firewall door 212L protect the systems which are not protected by circuit-breakers.
NOTE : The diagram located on PL3 fuse panel allows localization of fuses. Spare fuses are located on the cover fixed on door 212L.
The advisory panel, tachometer, control and landing gear control panel and engine monitoring cluster are supplied by the "BUS 1" bar. If this bus is lost or manually shed, the "BUS 3" bar automatically supplies these instruments through a relay located in PL3 fuse panel.
B. Bus bars
Bus bars are the elements which dispatch DC to the various circuits. They are located behind PL1 circuit-breaker panel.
 
C. "Pull-off" type circuit-breakers
In addition to protection of the alternator supply with a 60-amp "pull-off" type circuit-breaker labeled "ALT", the following "pull-off" type circuit-breakers have been installed :
 
中国通航网 www.ga.cn