C. By-pass valve
The by-pass valve provides connection between the normal distribution system and the emergency distribution system.
The by-pass valve is equipped with two MT23 and MT24 pressure switches for indicating. The by-pass valve is located between the firewall and the regulating valve.
AAAA
Validity : OPTION (14 V) 37-12-00 (BA) Page 2 JUN 01
 

  A - B59 electromechanical vacuum pump
B - K59 relay
C - By-pass valve

 
   ®
  
 @ 
143 70000AAA HYZ4000   

 
Emergency distribution - Identification and location of components
Figure 1
AAAA
Validity : OPTION (14 V) 37-12-00 (BA) Page 3 JUN 01
 
PAGE INTENTIONALLY LEFT BLANK
WA
Validity : OPTION (14 V) 37-12-00 (BA) Page 4 JUN 01
 
EMERGENCY DISTRIBUTION
DESCRIPTION AND OPERATION
1. GENERAL
In addition to the normal system, the aircraft can be equipped with an emergency vacuum system which supplies the power necessary for the operation of the gyroscopic instruments and of the directional gyro indicator in case of failure of the normal system pump.
The system consists of :
- B59 electromechanical vacuum pump,
- K59 relay,
- by-pass valve,
- the normal distribution system assembly,
- S59 "AUX SUCT" switch.
The system is electrically supplied by "BUS 3" bar.
2. LOCATION (Figure 1)
COMPONENT QTY AREA ACCESS DOOR REFERENCE
B59 electromechanical vacuum pump 1 210 218 37-12-01
K59 relay 1 210 218 37-12-00
By-pass valve 1 250 211L 37-12-00
Normal distribution system assembly 1 100 / 230 211L 37-11-00
S59 "AUX SUCT" switch 1 250 254L 37-12-00
Circuit breakers :    
- CB 59 "AUX SUCT" / PL1 / WM
- CB 58 "AUX SUCT" / PL1 / WM

3. DESCRIPTION
A. B59 electromechanical vacuum pump
The electromechanical vacuum pump supplies the gyroscopic instruments with the vacuum necessary for their operation in case of failure of the mechanical vacuum pump.
The electromechanical vacuum pump is electrically supplied by "BUS 3" bar and protected by a 10-Ampere "CB 59" circuit breaker.
The electromechanical vacuum pump is located under the cabin floor, on the L.H. side.
B. K59 relay
The electromechanical vacuum pump is electrically supplied via K59 relay, controlled by S59 "AUX SUCT" switch. K59 relay is located on the electromechanical vacuum pump support.